Upconversion Nanoparticle-Based Dot-Blot Immunoassay for Quantitative Biomarker Detection

Investor logo
Investor logo

Warning

This publication doesn't include Institute of Computer Science. It includes Faculty of Science. Official publication website can be found on muni.cz.
Authors

MÁČALA Jakub MAKHNEVA Ekaterina HLAVÁČEK Antonín KOPECKÝ Martin GORRIS Hans-Heiner SKLÁDAL Petr FARKA Zdeněk

Year of publication 2024
Type Article in Periodical
Magazine / Source Analytical Chemistry
MU Faculty or unit

Faculty of Science

Citation
Web https://pubs.acs.org/doi/10.1021/acs.analchem.4c00837
Doi http://dx.doi.org/10.1021/acs.analchem.4c00837
Keywords Photon-upconversion nanoparticle; Immunoassay; Dot-blot; Biomarker; Human serum albumin; Prostate-specific antigen; Cardiac troponin
Description Dot-blot immunoassays are widely used for the user-friendly detection of clinical biomarkers. However, the majority of dot-blot assays have only limited sensitivity and are only used for qualitative or semiquantitative analysis. To overcome this limitation, we have employed labels based on photon-upconversion nanoparticles (UCNPs) that exhibit anti-Stokes luminescence and can be detected without optical background interference. First, the dot-blot immunoassay on a nitrocellulose membrane was optimized for the quantitative analysis of human serum albumin (HSA), resulting in a limit of detection (LOD) of 0.19 ng/mL and a signal-to-background ratio (S/B) of 722. Commercial quantum dots were used as a reference label, reaching the LOD of 4.32 ng/mL and the S/B of 3, clearly indicating the advantages of UCNPs. In addition, the potential of UCNP-based dot-blot for real sample analysis was confirmed by analyzing spiked urine samples, reaching the LOD of 0.24 ng/mL and recovery rates from 79 to 123%. Furthermore, we demonstrated the versatility and robustness of the assay by adapting it to the detection of two other clinically relevant biomarkers, prostate-specific antigen (PSA) and cardiac troponin (cTn), reaching the LODs in spiked serum of 9.4 pg/mL and 0.62 ng/mL for PSA and cTn, respectively. Finally, clinical samples of patients examined for prostate cancer were analyzed, achieving a strong correlation with the reference electrochemiluminescence immunoassay (recovery rates from 89 to 117%). The achieved results demonstrate that UCNPs are highly sensitive labels that enable the development of dot-blot immunoassays for quantitative analysis of low-abundance biomarkers.
Related projects:

You are running an old browser version. We recommend updating your browser to its latest version.

More info