Role of different stent types in endoluminal IRE for recanalization of an occluded metal stent – mathematical model of temperature distribution
Autoři | |
---|---|
Rok publikování | 2024 |
Druh | Další prezentace na konferencích |
Fakulta / Pracoviště MU | |
Citace | |
Popis | In the mathematical model, substantial differences in temperatures were observed between the specific stents analysed. In the highest voltages with 1 mm interposed tissue, thermal effects of ablation were present. Limitations: This was a computer simulation. |