Safety and tolerability of second and third generation antipsychotic

Varování

Publikace nespadá pod Ústav výpočetní techniky, ale pod Lékařskou fakultu. Oficiální stránka publikace je na webu muni.cz.
Autoři

ČEŠKOVÁ Eva NOVOTNÝ Tomáš FLORIÁNOVÁ A. PÁLENSKÝ Vítězslav PŘIKRYL Radovan TOMANOVÁ J.

Rok publikování 2004
Druh Článek v odborném periodiku
Časopis / Zdroj Psychiatrie, časopis pro moderní psychiatrii
Fakulta / Pracoviště MU

Lékařská fakulta

Citace
Obor Psychiatrie, sexuologie
Klíčová slova safety and tolerability; antipsychotics; QT interval
Popis Prolongation of the QT interval is of concern since the pacients may be at risk for TdP, a serious ventricular arrythmia.In hospitalised psychiatric patients a 12-lead ECG was recorded, the QT interval was measured manually, the Bazett formula was used for correction. The total number of 375 ECG records was obtained. In 11 of 375 records(i.e.2,9%) the borderline or pathologics valuesof QT interval were found. The occurrence of abnormal QTc was lower than in so-far avilable literature. This could be connected with the change of spectrum of antipsychotics used, the general trend to lower doses of antipsychotics.
Související projekty:

Používáte starou verzi internetového prohlížeče. Doporučujeme aktualizovat Váš prohlížeč na nejnovější verzi.

Další info